Table 1: MR imaging protocol.

MR unit Siemens® skyra® with a magnetic field strength of 3 tesla
Series TR TE FoV NEX Resolution
Localizers Gradient echo T1, large FOV, quick acquisition time in all three planes as per vendor
Axial T2 (tse) 5000 88 22 cm 1 0.4 × 0.4 × 5 mm
Axial T1 (tse) 400 7.1 22 cm 2 0.6 × 0.6 × 5 mm
Axial FLAIR 9000 81 22 cm 2 0.7 × 0.7 × 5 mm
Coronal FLAIR (mpRAGE) 4680 84 22 cm 1 0.5 × 0.5 × 5 mm
Axial 3D T1 (SPACE) 1900 2.49 22 cm 1 0.9 × 0.9 × 0.9 mm
Axial 3D T2 3200 412 22 cm 1 1 × 1 × 1 mm
Axial SWI 400 4.92 22 cm 1 3 × 3 × 3 mm
Axial DWI 32 directions 700 95 22 cm 1 1.7 × 1.7 × 4 mm

FLAIR: Fluid Attenuation Inversion Recovery; SWI: Susceptibility Weighted Images; DWI: Diffusion Weighted Imaging; TR: Time of Repetition; TE: Time of Echo; FoV: Field of View; NEX: Number of Experiments.

The acronyms between brackets indicate the name of the pulse sequences as per the software of the magnetic resonance unit used for the study (Siemens® ).