Table 2: Pre-and postoperative biometry and intraocular pressure (IOP), intraocular lens (IOL) power and postoperative refraction of all 216 operated eyes.

Preoperative At follow-up examination
Mean SD Min Max Missing data Mean SD Min Max Missing data
Axial length (mm) 22.4 1.7 18.4 26.1 164 22.1 1.8 16.9 27.5 12
K1-readings (diopter) 42.9 1.8 37.5 46.3 154 43.5 2.7 36.8 53.0 11
K2- readings (diopter) 44.3 2.1 39.0 48.8 154 45.5 3.0 39.8 57.5 11
mean K-readings (diopter) 43.6 1.9 39.3 47.5 154 44.5 2.8 39.3 54.8 11
IOP (mmHg) 16.3 6.0 8.0 30.0 193 14.2 3.6 7.0 30.0 8
Power IOL inserted (diopter) (total group) 23.9 3.4 13.0 30.0 13
Subgroup where biometry done preoperatively 24.0 3.7 15.0 30.0
Subgroup where biometry not done preoperatively 23.8 3.6 14.0 30.0
Objective sphere used (diopter) -1.7 3.9 -12.0 13.0 21
Objective cylinder used (diopter) -1.3 1.4 -6.0 0.0 21
Objective spherical equivalent (diopter) -2.3 4.0 -15.0 12.5 21